2U_2_Bay_Hot_Swap_Redundant_ATX_Power_Supply_Rack_System.jpg

FRAKxxxMV: 2U, 2 Bay, Hot-Swap, Redundant, ATX Power Supply Rack System Product Specification

Product Description

This product is a 2U, 2 bay, 1+1, hot-swap, redundant, ATX power supply rack system incorporating individual power modules offering up to 6 outputs plus a 5V stdby in 360W, 420W, 480W, 540W, 600W, 660W and 750W power module increments. There is even a 24Vdc output to meet CompactPCI and VME platform requirements

Product Features

2U, 1+1, 2 Bay, Rack Mountable ATX Power System

Hot Swap Power Modules for Redundant Operation

Up to 6 Outputs with 5V Standby

Output Options: 3.3V, 5V, 12V, & 24V

                                                                         

AC Input

Voltage Input Range: 90-264Vac

Frequency Range: 47-63Hz

Phase: Single Phase

Typical Input Current: 7.1A at 115Vac input, full load

Power Factor Correction: 0.95 min @ 115Vac, full load

FRAKxxxMV Series Output Selection Matrix

  • PLEASE CONSULT FACTORY for OUTPUT/POWER CONFIGURATIONS

DC Output Characteristics

Set Point Accuracy: ±1.0% of Output Voltage (Nominal input; full load; 25°C)

Transient Response: Output voltage returns to within 1% in less than 2.5mS for a 50% load change and the peak transient does not exceed 5%

Overshoot: Turn-on and turn-off overshoot should not exceed 10% over nominal voltage

Holdup Time: 16mS

Electrical Characteristics

Switching Frequency: 300KHz Fixed

Efficiency: 85% min (At 20%/50%/100% load and at 115Vac nominal input)

Turn On Delay: 100 to 200mS (To nominal output voltage)

Isolation Voltage (High Voltage Withstand):

Primary to Secondary: 4242Vdc

Primary to Ground: 2800Vdc

Protection

Over Current Limit: 130% maximum for +12V output (V1) and 150% max for 3.3V & 5V outputs

Over-Voltage Setpoint: 108 to 125% of output voltage. Unit latched 1 minute, recycle AC input to reset

Short Circuit: Auto-recovery after short circuit condition is removed and cycle ON/OFF to reset

No-load Operation:  No damage or hazardous condition will occur with all the DC output connectors disconnected from the load. The power supply may latch into the shutdown state.

Environmental

Operating Temperature: -10º to +50ºC (Ambient air)

Storage Temperature: -40º to +85ºC

Operating Humidity: 10% to 90% RH, Non-condensing

Storage Humidity: 5% to 95% RH, Non-condensing

Operating Altitude: Sea-level to 16,000 ft.

Conducted & Radiated EMI: Designed to meet EN55022 Level B, CISPR 22 Class B, FCC Part J Class B

Immunity: Designed to CE: EN55024:2010/IEC61000

Safety

Safety Agency Certifications: cUL (cTUVus): UL62368-1, TUV: EN62386-1, CB: IEC62368-1

Cooling

Internally Cooled: Each power module incorporates 2 high reliable DC fans

Mechanical

Enclosure: Metal chassis, enclosure, non-finish.

Outline Dimensions: 150mm X 185mm X 86mm (W X L X H) – not including I/O connectors  

Weight: 6.5lbs. (2948 grams)

I/O Cable & Connectors: Standard ATX configuration (Custom cabling/connectors available)

Optional Features, Controls or Alarms

PWR_OK (Power Good Signal)

PS_ON (DC Soft Start)

+5Vsb (Standby Voltage)

I2C/PSMI Output Signals

Note

Product specifications subject to change without notice